Miernik mocy optycznej GPON/XGPON/10GPON
VIAVI OLP-87/87P
SmartClass™ Fiber PON Power Meter and Microscope
The Viavi Solutions OLP-87 is an FTTx/PON power meter for use in qualifying, activating, and troubleshooting B-PON,
E-PON, G-PON, and next-generation, high-speed 10 G PONs such as XG-PON and 10G-EPON networks. As part of the Viavi Solutions SmartClass Fiber family, the OLP-87 combines a high-performance λ-selective FTTx/PON meter with pass/ fail fiber inspection analysis into one portable solution. These combined capabilities guarantee service providers a lifetime of system performance from their network connectivity and gives contractors an essential tool for delivering best-in- class, reliable networks to their customers.
The OLP-87 is ideal for end-of-line testing, activation, and maintenance of all FTTx/PON signals. The through-mode capability can simultaneously measure voice, data, and RF video signals on fiber at 1490/1550/1578 nm downstream and 1270/1310 nm burst mode upstream.
The OLP-87 is compatible with the P5000i digital analysis microscope so users can check fiber end-face quality and get pass/fail acceptance results with one button push. The OLP-87P features an integrated patch-cord microscope (PCM) for added value and improved workflow efficiency.
Users can easily save test results and generate certification reports to document work quality. Integrating these capabilities into one system drives technician behavior toward implementing today’s best practices in a seamless workflow that optimizes efficiency and reliability so they complete the job right—the first time.
The handheld OLP-87 can be used anywhere today’s fiber technicians go, up poles or down holes. Technicians get ultimate flexibility and performance from this powerful, easy-to-use solution that can help any technician become an instant fiber expert.
KeyFeatures
Miernik VIAVI OLP-87 jest dedykowany do aktywacji i diagnozowania sieci G- PON, B-PON, E- PON oraz sieci dostępowych następnych generacji 10G PON takich jak XG-PON i 10G-EPON. W ramach tego urządzenia dostępny jest selektywny pomiar pass-through, pomiar szerokopasmowy oraz współpraca przez USB z sondą inspekcyjną FBP-P5000i dzięki czemu bezpośrednio na przyrządzie uzyskujemy wynik automatycznej analizy pass/fail w odniesieniu do standardu IEC 61300-3-35.
Power Meter | OLP-87/87P 1310/1490 nm | OLP-87/87P 1310/1490/1550 nm | OLP-87/87P XG-PON 1270/1310/1490/1550/1578 nm |
B-PON (ITU-T G983.x) | n | n | n |
G-PON (ITU-T G984.x) | n | n | n |
E-PON (IEEE 802.3av) | n | n | n |
XG PON (ITU-T G.987) | n | ||
10G-EPON (IEEE 802.3av) | n | ||
RF video signals 1550nm | n | n | |
Broadband power meter | n | Option | Option |
FTTx Mode
Upstream 1270 nm, burst mode
Power measurement range | –40 to +13 dBm1 | ||
Maximum permitted input level | +17 dBm | ||
Spectral passband | 1260 to 1280 nm |
Upstream 1310 nm, burst mode
Power measurement range | –40 to +13 dBm1 | –40 to +13 dBm1 | –40 to +13 dBm1 |
Maximum permitted input level | +17 dBm | +17 dBm | +17 dBm |
Spectral passband | Broadband | 1260 to 1360 nm | 1290 to 1330 nm |
Downstream 1490 nm
Power measurement range | –50 to +13 dBm | –50 to +13 dBm | –50 to +13 dBm |
Maximum permitted input level | +15 dBm | +15 dBm | +15 dBm |
Spectral passband | Broadband | 1480 to 1500 nm | 1480 to 1500 nm |
Downstream 1578 nm
Power measurement range | –50 to +13 dBm | ||
Maximum permitted input level | +15 dBm | ||
Spectral passband | 1573 to 1583 nm |
RF video signals 1550nm
Power measurement range | –50 to +26 dBm | –50 to +26 dBm | |
Maximum permitted input level | +27 dBm | +27 dBm | |
Spectral passband | 1535 to 1565 nm | 1535 to 1565 nm | |
Pass-through insertion loss | <1.5 dB2 | <1.5 dB2 | <1.5 dB2 |
Power uncertainty | ±0.5 dB2,3 | ±0.5 dB2,3 | ±0.5 dB2,3 |
Calibrated wavelengths FTTx mode | 1310/1490 nm | 1310/1490/1550 nm | 1270/1310/1490/1550/1578 nm |
Broadband Mode
Optical interface | on OLT port (SC switchable adapter) | Separate port (2.5 mm UPP adapter) (1.25 mm UPP optional) | Separate port (2.5 mm UPP adapter) (1.25 mm UPP optional) |
Power measurement range | –50 to +13 dBm | –50 to +13 dBm | –50 to +13 dBm |
Maximum permitted input level | +15 dBm | +15 dBm | +15 dBm |
Power uncertainty | ±0.5 dB4, 5 | ±0.2 dB (±5%)4, 7 | ±0.2 dB (±5%)4, 7 |
Calibrated wavelengths broadband mode | 1310/1490/1550/1625 nm | 1310/1490/1550/1625 nm | 1310/1490/1550/1625 nm |
Wavelength range, settings | 1260 to 1625 nm in 1 nm steps | 1260 to 1625 nm in 1 nm steps | 1260 to 1625 nm in 1 nm steps |
Tone detection | 270 Hz 1 kHz/2 kHz | 270 Hz 1 kHz/2 kHz | 270 Hz 1 kHz/2 kHz |
Auto functions6 | Auto-λ / Multi-λ function | Auto-λ / Multi-λ function | Auto-λ / Multi-λ function |
General
Technical
Display | High-contrast 3.5” color LCD with touch-screen functionality |
Display resolution | 0.01 dBm/0.001 µW |
Measurement units | dB, dBm, W |
ORL4, 8 | >60 dB |
Fiber inspection | Via external probe P5000i (option) with individual naming, and via integrated patch cord microscope for OLP-87P versions |
Live image | 320 x 240 x 8 bit grey, 10 fps |
Threshold sets | >1000 configurable threshold sets with individual naming, and via integrated patch cord microscope for OLP-87P versions |
Data memory | 10.000 measurement results |
Data readout | Via client USB interface |
Remote control capability | Via USB or Ethernet |
Electrical interfaces | 2 x USB host, 1x micro USB, Ethernet |
Power source | AC adaptor, 8x AA alkaline, or rechargeable LiION battery pack (option) |
Optical connectors | SC Switchable Optical Adapter (FC, ST and LC also available) |
Recommended recal. Inte | 3 years |
Dimensions (H x W x D) OLP-87 OLP-87P | 208 x 112 x 64 mm/750 g (8.2 x 4.4 x 2.5 in/1.6 lb) 208 x 153 x 64/850 g (8.2 x 6.0 x 2.5 in/1.85 lb) |
Operating temperature range | –10 to +55°C (14 to 122°F) |
Storage temperature range | –20 to +70˚C (–4 to 158°F) |
Oferta usług utrzymania systemów obejmuje 6 pakietów usług pomocy technicznej VECTOR TECH SOLUTIONS: V-AID Service / EW / NBD / NBD+EW / 24h / 24h+EW. Umożliwiają one wykorzystanie potencjału Firmy VECTOR w zakresie codziennego wsparcia technicznego, rozwiązywania problemów, szybkiego reagowania na problemy krytyczne w sieci oraz utrzymania systemu na najwyższym poziomie wydajności oraz planowania rozwoju sieci.
Produkt niedostępny już w sprzedaży.